Circular Coverage Contours
Q: I computed a coverage contour with TAP but it plots
as a perfect circle. What could cause this?
A: Since coverage contours depend on terrain, antenna
pattern, etc., a coverage plot that is circular should raise
a question about the settings used for the study.
The types of input values that generate a circular coverage
plot can create either a very small circle or a large circle.
(TAP performs numerous checks of the values you enter to try to
warn you of unusual or incorrect parameters, but checking the
following information is a good idea if you suspect the contour
computed as a circle is not correct.)
Small Contours
If the coverage contour you computed is plotted on a coverage
map as a very small circle right around the transmitter site,
it indicates that the computed field values are very low, and
the distance to the contour is therefore very small. Check the
following input parameters:
- Transmitter ERP and units: Be sure the Effective Radiated
Power is entered correctly, and 100Watts (100W) is not set as
100milliWatts (100mW), etc.
- Mobile facility antenna height: Be sure the
Mobile
Facility Database record used for the study has the antenna
height correctly set. For example, if the correct height is 6ft
AGL (Above Ground Level) and the mobile height is set as 6ft
MSL (above Mean Sea Level), the mobile will be 'buried"
in most parts of the country.
- Mobile facility required field value: The contour level computed
is based on the "Required
Field" value for the mobile facility. This value can
be computed in the Mobile Facility Lookup, or from the Utilities
menu in TAP. This is the field
value in dBu that produces the manufacturer's specified receiver
input (typically in dBm, uV, etc.) under the circumstances you
specify (receiver antenna gain,
line loss, body
or building
loss, etc.) If this value is abnormally high, the resulting contour
will be very small, showing that only a small area receives this
high signal level.
Large Contours
If the coverage contour you computed is plotted on a coverage
map as a large circle, typically out to the distance of the radials
you specified, check the following input parameters.
- Transmitter ERP and units: Be sure the Effective Radiated
Power is entered correctly, and 100Watts (100W) is not set as
100kiloWatts (100kW), etc.
- Mobile facility antenna height: Be sure the
Mobile
Facility Database record used for the study has the antenna
height correctly set. For example, if the correct height is 6ft
AGL and the mobile height is set as 600ft the computed field
will be unusually high, since the clearance of the signal path
will be above most of the terrain.
- Mobile facility required field value: The contour level computed
is based on the "Required
Field" value for the mobile facility. This value can
be computed in the Mobile Facility Lookup, or from the Utilities
menu in TAP. This is the field
value in dBu that produces the manufacturer's specified receiver
input (typically in dBm, uV, etc.) under the circumstances you
specify (receiver antenna gain, line loss, body or building loss,
etc.) If this value is abnormally low, the resulting contour
will be very large, showing that only a large area receives this
low signal level.
- Radial Length: For the analytical propagation
models that use terrain elevation values (Bullington,
Longley-Rice,
Okumura, etc.)
and not just the height above average terrain (HAAT) along the
paths (Broadcast, Carey, etc.), the contour is computed by interpolating
the computed field strength values along each radial. If the
contour value is beyond the end of a radial, the distance is
set to the radial length. If this happens on all of the radials,
a circular contour plot results. For example, suppose you want
to plot the 16dBu contour (assuming you use the Required Field
function described above to be sure this is the correct value).
If you compute the field values along each radial out to 60km,
but the computed values along the radial out to that distance
never fall below 40dBu (because of the power and good site location
of the fixed facility), the program will not find the 16dBu value
along the radials, so the contour will be placed at the end of
each radial, or 60km. This would indicate that the coverage for
the fixed and mobile specifications you used covers the entire
60km radius around the transmitter site. However, if you need
to see the actual predicted limits of the contour, you can run
the study again and specify a larger distance value out from
the transmitter site. You can use the TAP
Single
Point Field program to compute field values from the fixed
facility on individual radials to get an idea of the distance
range of the field level of the contour. In this example, using
the Single Point Field program to compute the field at 80km,
100km, 120km, etc., on both the radial with the best expected
coverage would you an idea of the range of the study you want.
- Contour percentage value: As described above, the contour
value is interpolated
from the field strength points along each radial. The "percentage"
value specified for the calculation affects the distance computed
for the contour along each radial. For example, if a percentage
of 95% is used, then a few points along the radial below 16dBu
(in the example) can be offset by a large number of higher field
level points. This is typically a more realistic representation
of the coverage using a contour. If the contour is drawn at the
first point along the radial where the field drops below the
specified value (such as behind an isolated hill, or in a small
valley along the radial), the contour distance on that radial
will be unrealistically restricted if numerous points beyond
that hill or valley have a much higher value. Using this percentage
value gives you control over the interpolation process. However,
if you set the percentage value too low (such as 50%, or 10%),
the interpolation becomes almost meaningless, since the contour
can be placed much farther than is realistic. Suppose the computed
field at 30km is 16dBu, and every point beyond that distance
is much lower than 16dBu. If the percentage value is set at 90%,
or 95%, the contour would be placed within a few points of the
30km distance. But if the percentage is set at 50%, the contour
could be placed as far as 60km out on the radial, since 50% of
the points (in the first 30km) are above the value, and 50% (from
30 to 60km) are lower. Typically, percentage values for the contour
calculation should be 90% or above. Special requirements for
interference contours or other reasons to set lower percentage
values should be accomplished using the reliability and confidence
settings in the particular model, such as Longley-Rice
or Okumura.
Search SoftWright Website